Technical data

Technical data

Product designation

CP6606-0001-0020

Weight

0.9 kg

Supply voltage

22–30 VDC (24 VDC power supply unit, NEC class 2)

Power consumption

Data sheet for power consumption and power loss in the download finder:

https://www.beckhoff.com/en-en/support/download-finder/search-result/?download_group=691754572

Protection rating

Front IP54, rear IP20

Vibration resistance (sinusoidal vibration)

EN 60068-2-6:

10 to 58 Hz:

0.035 mm

58 to 500 Hz:

0.5 G (~ 5 m/ s2)

Shock resistance (shock)

EN 60068-2-27:

5 G (~ 50 m/s2), duration: 30 ms

EMC interference immunity

conforms to EN 61000-6-2

EMC interference emission

conforms to EN 61000-6-4

Permissible ambient temperature

Operation: 0 °C ... +55 °C (+45 °C with wall mounting frame)

Transport/storage: -20 °C ... +65 °C

Permissible relative air humidity

Maximum 95%, no condensation

Transport and storage

The values for air humidity and shock resistance are to be observed during transport and storage and in operation. Suitable packaging of the panel PC can improve its shock resistance during transportation.