Intended use
The device is intended for use as a control system for automation, visualization and communication in machine and system engineering.
The front of the device is designed for an IP54 working environment. There is complete protection against contact and against dust in harmful quantities, as well as protection against splash water on all sides.
The rear side is designed for a working environment that meets the IP20 protection rating. This involves finger protection and protection against solid foreign objects up to 12.5 mm. There is no protection against water. Operation of the device in wet and dusty environments is not permitted.
The specified limits for technical data must be adhered to.
The device can be used within the documented operating conditions.
Improper use
Do not use the device outside the documented operating conditions.