Power supply CP39xx-1401-0010 and wiring push button extension
The Control Panel CP39xx-1401-0010 is supplied with a nominal input voltage of 24 V. The power supply and the wiring of the push button extension are connected via the 19-pin M23 socket.
Pin | Signal |
---|---|
1 | Emergency stop (normally closed contact 1) |
2 | Emergency stop (normally closed contact 1) |
3 | Emergency stop (normally closed contact 2) |
4 | Emergency stop (normally closed contact 2) |
5 | Short-stroke button S2 (normally open contact) |
6 | GND |
7 | Short-stroke button S2 (normally open contact) |
8 | LED S2 (green) |
9 | Short-stroke button S3 (normally closed contact) |
10 | Short-stroke button S3 (normally closed contact) |
11 | LED S3 (red) |
12 | PE |
13 | Short-stroke button S4 (normally open contact) |
14 | Short-stroke button S4 (normally open contact) |
15 | LED S4 (blue) |
16 | Reserve |
17 | GND LED S2/ S3/ S4 |
18 | Reserve |
19 | + 24 V DC |