Disassembly and disposal
To be able to dismount the panel PC from the mounting arm, you must first have disconnected the power supply and the cables (see Chapter 6.1 Disconnecting the power supply and cables).
Disassembly mounting arm tube
Notice | |
Damage to property due to falling down If the panel PC is suspended from the ceiling and you undo the cap nut of the mounting arm adapter without securing it, the panel PC will fall down.
|
To remove the panel PC from the mounting arm tube, follow the steps below, shown in Figure 20:
- 1. Loosen the slotted nut of the mounting arm adapter with a hook wrench size 58-62 (C9900-Z263) in counterclockwise direction (section A).
- 2. Unscrew the hexagon socket screw (1) a few turns with a 3 mm Allen key (section A).
- 3. Pull the mounting arm tube out of the mounting arm adapter (section B).
- 4. Pull the connecting cables out of the mounting arm tube.
- 5. Screw in the hexagon socket screw until it no longer protrudes on the outside.
- You have removed the mounting arm tube from the mounting arm adapter.
Disassembly toolboard and handle
To remove the handle from the device, loosen the two M5 screws on the bottom of the device (see Fig. 21). Make sure that the handle is secured against falling.
To remove a toolboard from the device, follow the steps shown in Figure 22. During disassembly, ensure that the individual components are secured against falling:
- 1. Loosen the two M4 screws of the strain relief (section A).
- 2. Loosen the four M5 screws on the toolboard (section B).
- 3. Loosen the three M5 screws of the toolboard bracket (section C).
- You have dismantled the toolboard.
Disposal of the panel PC
When disposing of the panel PC, be sure to observe the national electronic waste regulations.