Interface description
In the basic configuration, the panel PC includes the following interfaces:
- Power supply (X101)
- Ethernet RJ45 (X102)
- USB
The voltage socket and the Ethernet interface are located on the rear side in the connection compartment of the device (1). The USB interface is located behind a screw cap in the side panel of the device (2). To access the USB interface, remove the screw cap from the housing.
With a mounting arm adapter installed on the panel PC, you must first gain access to the connection compartment of the device. Follow the steps below, as shown in Fig. 4:
- 1. Insert a screwdriver into the recesses on the bottom of the mounting arm adapter (section A).
- 2. Bend the cover slightly outwards so that you can push out the latching lugs.
- 3. Slide the cover upwards off the mounting arm adapter (section B).
- You now have access to the connection compartment of the panel PC.
- 4. Then push the cover back onto the mounting arm adapter from top to bottom until the latching lugs snap back into place.