Interface description

In the basic configuration, the panel PC includes the following interfaces:

The voltage socket and the Ethernet interface are located on the rear side in the connection compartment of the device (1). The USB interface is located behind a screw cap in the side panel of the device (2). To access the USB interface, remove the screw cap from the housing.

Interface description 1:
Fig.3: Interfaces basic configuration

With a mounting arm adapter installed on the panel PC, you must first gain access to the connection compartment of the device. Follow the steps below, as shown in Fig. 4:

1. Insert a screwdriver into the recesses on the bottom of the mounting arm adapter (section A).
2. Bend the cover slightly outwards so that you can push out the latching lugs.
3. Slide the cover upwards off the mounting arm adapter (section B).
Interface description 2:
Fig.4: Access connection compartment
You now have access to the connection compartment of the panel PC.
4. Then push the cover back onto the mounting arm adapter from top to bottom until the latching lugs snap back into place.