Fan cartridge replacement
Notice | |
Incorrect fan type The device may be damaged if the wrong type of fan is installed.
|
The fans ensure optimal cooling of the device. Order replacement fans only from Beckhoff. Please get in touch with your Beckhoff sales contact.
You can replace the fan cartridge while the device is in operation. Insert the new fan cartridge immediately after removing the old one.
If you look at the device from the back, the fan cartridge is located in the right side of the PC. To replace the fan cartridge, follow the steps below:
- 1. Loosen the four M3 screws of the fan cartridge.
- 2. Remove the fan cartridge.
- 3. Insert the new fan cartridge.
- 4. Retighten the four M3 screws.
- You have now replaced the fan cartridge.
The old fan must be disposed of in accordance with the national electronic waste regulations.