Replacing the battery
Notice | |
Incorrect battery type Using any other battery may cause fire or explosion.
|
Notice | |
Battery damage Incorrect handling of the motherboard battery can damage it.
|
Notice | |
Failure of the electronics due to mechanical damage Scratches or damaged components on PCBs can cause the electronics to fail.
|
The device does not contain a lithium-ion battery. The motherboard battery is a CR2032 lithium-metal cell. It is used to supply power to the clock integrated on the motherboard. If the battery is depleted or missing, the date and time are displayed incorrectly.
Battery type | Electrical properties (at 20 °C) | Dimensions | |||
---|---|---|---|---|---|
Nominal voltage | Nominal capacity | Diameter | Height | Weight | |
CR2032 | 3.0 V | 225 mAh | 20.0 mm | 3.20 mm | 3.1 g |
Chapter 7.2 Maintenance shows how to gain access to the battery.
To replace the battery, follow the steps below:
- 1. Pull the battery out of the panel PC with needle-nose pliers (see Fig. 27).
- 2. Insert the new battery into the PC by hand. Pay attention to the correct polarity. The negative pole of the battery must face the display.
- You have replaced the battery.
Battery disposal
To dispose of the battery, remove it, tape off the poles and put it in the battery disposal.