Disassembly and disposal

Before you can remove the device from the control cabinet, you must first disconnect the power supply and the cables (see Chapter Disconnecting the power supply and cables).

To remove the device from the control cabinet, follow the steps below:

1. Loosen the clamping levers with a 3.0 mm Allen key (sections A and B). Make sure that the device is secured against falling out until it is removed from the wall.
2. Turn the clamping levers by 90° onto the device (section C).
Disassembly and disposal 1:Fig.24: Dismantling the control cabinet
3. Remove the device from the corresponding cutout in the control cabinet wall.
Disassembly and disposal 2:Fig.25: Wall removal
You have successfully removed the device from the control cabinet.

Disposal of the panel PC

When disposing of the device follow the national electronic scrap regulations. In order to dispose of the device, it must be removed and fully dismantled. Dispose of the components in the following way: