Replacing the storage media

For new storage media, please contact your Beckhoff Sales only. Hard disks from Beckhoff are optimized for industrial applications. SSDs from Beckhoff have a considerably higher lifetime expectancy than commercially available SSDs.

Disposal of storage media

Delete confidential or technologically important data from the storage media before disposing of it. If a storage medium is defective, you must destroy it mechanically to prevent access to the data.

The old storage media must be disposed of in accordance with the national electronic waste regulations.

Data transmission before replacement

If you want to exchange a storage medium according to Beckhoff's recommendation, you must copy the data from the old to the new storage medium. You can use the Beckhoff Service Tool (BST) for this purpose. BST is a graphical backup and restore program for devices with a Windows operating system. You can create an image of your operating system and use it to back up the operating system. Then you can restore the created image to a new data carrier. The BST is available on a bootable BST USB flash drive. This includes Windows and a backup tool. Select the size of the BST USB flash drive according to the size of the backup copy of your operating system. You can then keep the flash drive as a backup copy. For this purpose, the BST USB flash drives are designed for particularly long data preservation by means of special flash. For more information on the function of the BST, please refer to the corresponding manual.

If your storage medium is defective and there is no backup, Beckhoff Service can provide you with a fresh Windows image. For this to be possible, your Beckhoff device must already have been delivered with a valid operating system license. After installing the fresh image, the applications must be reinstalled.

Replacing CFast

Chapter 7.2.1 Access to device components shows how to access the CFast.

To replace the CFast, follow the steps shown below in Figure 26:

1. Press frontally against the CFast (section A).
The CFast now protrudes from the PC (section B).
2. Pull the CFast out of the PC (section C).
Replacing the storage media 1:Fig.28: Replacing the CFast
3. Insert the new CFast into the PC.
4. Press frontally against the protruding CFast.
The CFast is now fully inserted in the PC. You have replaced the CFast.

Exchange SSD

Chapter 7.2.1 Access to device components shows how to access the SSD.

Proceed as follows to change the SSD:

1. Remove the SSD from the PC by pulling forcefully on the protruding Beckhoff sticker (see fig. 27).
Replacing the storage media 2:Fig.29: Exchange SSD
2. Insert the new SSD into the PC in the same orientation up to the stop.
You have replaced the SSD.