Installation in the control cabinet
Notice | |
Extreme environmental conditions Extreme environmental conditions can cause damage to the device.
|
Notice | |
Incorrect installation Incorrect installation in a control cabinet prevents air circulation in the device and causes impaired functioning.
|
The device is designed for installation in the front of a control cabinet in machine and system engineering. The environmental conditions specified for operation must be observed.
Only install the device in the control cabinet with the power supply facing upwards.
Using different mounting plates, you can align the cable entry based on the application requirements.
Figure 9 shows the two available mounting plates: the standard mounting plate 1 and the optional mounting plate 2. Mounting plate 1 is mounted on the rear panel of the industrial PC and mounting plate 2 on the right-hand side panel. In both cases, four M4x8 countersunk head Philips screws are used for mounting.
The basic version of the industrial PC is supplied with the mounting plate 1 already mounted as shown in Fig. 9. Mounting plate 2 is not included in the scope of delivery. You can choose the following ordering options:
- C9900-M653: Mounting plate on the side panel instead of the rear panel