Technical data

Technical data

Product designation

C6925

Dimensions (W x H x D)

65 x 223 x 121 mm, without mounting plate

Weight

1750 g in basic configuration

Supply voltage

22-30 V DC (24 V DC power supply unit)

NEC Class 2

Power consumption

Data sheet for power consumption and power loss in the download finder:

https://www.beckhoff.com/en-en/support/download-finder/search-result/?download_group=691754572

Secure element

C6925-0030: fTPM 2.0 not enabled

C6925-0040: fTPM 2.0 enabled

(see TPM documentation)

Protection rating

IP20

Vibration resistance (sinusoidal vibration)

EN 60068-2-6: 10 to 58 Hz: 0.035 mm

58 to 500 Hz: 0.5 G (approx. 5 m/s2)

Shock resistance (shock)

EN 60068-2-27: 5 G (approx. 50 m/s2), duration: 30 ms

EMC interference immunity

conforms to EN 61000-6-2

EMC interference emission

conforms to EN 61000-6-4

Permissible ambient temperature

0 °C to 55 °C (operation)

-25 °C...+65 °C (transport/storage)

Permissible air humidity

Maximum 95 %, no condensation

Transport and storage

The values for air humidity and shock resistance are to be observed during transport and storage and in operation. The shock resistance during transport can be improved by packing the industrial PC appropriately.