Installing the supply cable

Mount the cable for the power supply to the industrial PC using the material provided for the connector assembly. It consists of an 8-pin connection strip and a strain relief housing with cable tie.

Assembly of the supply cable

First mount the plug on the cable as follows:

1. Remove the insulation from the cable ends (8-9 mm).
2. Screw the cable ends into the 8-pin connection strip. For the pin assignment of the connector, see Chapter 3.2.1 Power supply.

Assembly of strain relief housing

Now mount the strain relief housing on the previously connected plug and supply cable as shown in Fig. 17:

  1. Thread the cable tie into the lower part of the strain relief housing (section A).
  2. Insert the connection strip into the lower part of the strain relief housing (section B).
  3. Tighten the cable tie and remove the plastic tab (section C).
  4. Attach the upper part of the strain relief housing by snapping it onto the lower part (section D).
Installing the supply cable 1:
Assembly of strain relief housing