Power supply
In its basic configuration, the industrial PC is equipped with a 100-240 V AC, 50-60 Hz full range power supply unit.
The following table lists the maximum current carrying capacity of the 100–240 V AC power supply:
Output voltages power supply unit | Current load 100-240 V AC power supply unit max. |
|---|---|
+3.3 V | 30 A |
+5 V | 30 A |
+12 V total | 100 A |
-12 V | 0.8 A |
+5 V stand by | 4.0 A |
The total power output of the +3.3 V and +5 V lines must not exceed 100 W. The maximum total current for the +12 V outputs must not exceed 50 A.
The power supply is connected via the IEC socket (X101) on the top of the industrial PC. This is an IEC C20 socket. The connection cable supplied has an IEC C19 coupling. The assignment of the socket includes the protective conductor (1), a neutral conductor (2) and an outer conductor (2).