Power supply

In its basic configuration, the industrial PC is equipped with a 100-240 V AC, 50-60 Hz full range power supply unit.

The following table lists the maximum current carrying capacity of the 100–240 V AC power supply:

Current carrying capacity power supply unit

Output voltages power supply unit

Current load 100-240 V AC power supply unit max.

+3.3 V

30 A

+5 V

30 A

+12 V total

100 A

-12 V

0.8 A

+5 V stand by

4.0 A

The total power output of the +3.3 V and +5 V lines must not exceed 100 W. The maximum total current for the +12 V outputs must not exceed 50 A.

The power supply is connected via the IEC socket (X101) on the top of the industrial PC. This is an IEC C20 socket. The connection cable supplied has an IEC C19 coupling. The assignment of the socket includes the protective conductor (1), a neutral conductor (2) and an outer conductor (2).

Power supply 1:Fig.3: IEC socket