Replacing the battery
| |
Incorrect battery type Using a different type of battery can lead to a fire or explosion.
|
| |
Incorrect handling of the battery Handling the motherboard battery incorrectly can cause an explosion.
|
Notice | |
Failure of the electronics due to mechanical damage Scratches or damaged components on PCBs can cause the electronics to fail.
|
The device does not contain a lithium-ion battery. The motherboard battery is a CR2032 lithium-metal cell. It is used to supply power to the clock integrated on the motherboard. If the battery is depleted or missing, the date and time are displayed incorrectly.
Battery type | Electrical properties (at 20 °C) | Dimensions | |||
|---|---|---|---|---|---|
Nominal voltage | Nominal capacity | Diameter | Height | Weight | |
CR2032 | 3.0 V | 225 mAh | 20.0 mm | 3.20 mm | 3.1 g |
The motherboard battery is located inside the device. Chapter 7.2.1 Access to device components shows how to open the device.
To change the battery, proceed as follows:
- 1. Bend the hook on the battery holder slightly outward (section A).
- 2. Pull the battery out of the holder with needle-nose pliers (section B).
- 3. Insert the new battery into the holder. Make sure that the positive pole points towards the hook.
- You have successfully replaced the battery.
Battery disposal
To dispose of the battery, remove it, tape off the poles and put it in the battery disposal.