Switching the industrial server on and off

Notice

Public networks

Connecting the device to public networks without additional protective measures can compromise the safety of the device.

  • Protect the device before connecting it to public networks.

Notice

Data loss due to switching off the device while the software is running

Switching off the device before the running software is terminated and the operating system is shut down can lead to data loss.

  • Quit the running software and shut down the operating system before switching off the device.

The industrial server has its own power switch. Switching the system on or off or connecting or disconnecting the power supply to the device starts or switches it off. To avoid data loss, close the running software and shut down the operating system properly before switching off the device.

Starting the device with a USB stick inserted when using TwinCAT is not possible. The TwinCAT System ID changes. If you sometimes need to start your device with a USB stick inserted, you can integrate a TC license terminal into an EtherCAT terminal strip.

There is a UID (Unit Identification Purpose) button with LED in the connection section of the device. You can use this button to check whether the device is in operation or switched off. If you press the UID button, the blue UID LED lights up when the device is running. If you press the button again, the display is disabled.

Driver installation

When you switch on the device for the first time, the optionally pre-installed operating system will be started. For any additional hardware you have connected, you have to install the drivers yourself afterwards. In addition, the Beckhoff Device Manager starts automatically. The Device Manager is a software from Beckhoff that supports you in configuring the device.

If you have ordered the device without an operating system, you must install this and the driver software for the additional hardware you have connected and for the components inside the device. Please follow the instructions in the documentation for the operating system and the additional components.