Replacing the battery
Notice | |
Incorrect battery type Using any other battery may cause fire or explosion.
|
Notice | |
Battery damage Incorrect handling of the motherboard battery can damage it.
|
Notice | |
Failure of the electronics due to mechanical damage Scratches or damaged components on PCBs can cause the electronics to fail.
|
The device does not contain a lithium-ion battery. The motherboard battery is a CR2032 lithium-metal cell. It is used to supply power to the clock integrated on the motherboard. If the battery is depleted or missing, the date and time are displayed incorrectly.
Battery type | Electrical properties (at 20 °C) | Dimensions | |||
---|---|---|---|---|---|
Nominal voltage | Nominal capacity | Diameter | Height | Weight | |
CR2032 | 3.0 V | 225 mAh | 20.0 mm | 3.20 mm | 3.1 g |
Chapter 7.2.1 Access to device components shows how to access the battery.
To change the battery, proceed as follows:
- 1. Bend the hook on the battery holder slightly outward (section A).
- 2. Pull the battery out of the holder with needle-nose pliers (section B).
- 3. Insert the new battery into the holder. Make sure that the polarity is correct, as shown.
- You have successfully replaced the battery.
Battery disposal
To dispose of the battery, remove it, tape off the poles and put it in the battery disposal.