Power supply

In its basic configuration, the industrial PC is equipped with a 100-240 V AC, 50-60 Hz full-range power supply unit.

Current carrying capacity power supply unit

Output voltages power supply unit

Current load 100-240 V AC power supply unit max.

+3.3 V

14 A

+5 V

16 A

+12 V1

16 A

+12 V2

16 A

-12 V

0.5 A

+5 V stand by

3.0 A

-5 V

0.3 A

The power supply is connected via the IEC socket (X101) on the top of the industrial PC. The assignment includes a protective conductor (1), a neutral conductor (2) and an outer conductor (2).

Power supply 1:Fig.3: IEC socket

Optionally, you can order the industrial PC with a 24 V DC power supply unit. In this case, the industrial PC is supplied with a nominal voltage of 24 V. A 5-pin socket is used for the connection of the power supply (X101) as well as the external wiring (X102) of the industrial PC.

The main supply voltage is applied between PIN 1 (24 V) and PIN 2 (0 V) of the voltage socket (X101). If the industrial PC is equipped with an integrated uninterruptible power supply (UPS), you can also connect an external battery pack to PIN 4 and 5.

Power supply 2:Fig.4: Voltage socket pin numbering
Voltage socket (X101) pin assignment

Pin

Signal

Description

1

+24 V

24 V supply voltage, positive pole

2

-

24 V supply voltage, negative pole

3

Power supply 3:

Protective earth

4

+BAT

Positive pole of the battery pack

5

-BAT

Negative pole of the battery pack

The positive pole of the supply voltage at PIN 1 of the voltage socket (X101) is looped through to PIN 5 of the socket (X102). PIN 5 thus serves as the positive pole for PC-ON.

Power supply 4:Fig.5: Socket external wiring pin numbering
Socket external wiring (X102) pin assignment

Pin

Signal

Description

1

-24 V UPS

Negative pole UPS output

2

+24 V UPS

24 V UPS output 2.5 A

3

P-S

Output power status, minus is the negative pole of the power supply (X101)

4

PC-ON