Disconnecting the power supply and cables
CAUTION | |
Risk of electric shock Dangerous touch voltages can lead to electric shock. To avoid electric shock, observe the following:
|
Before you remove the industrial PC from the control cabinet, you must disconnect the cables and the power supply.
Disconnecting the power supply
Proceed as follows to disconnect the 100-240 VAC power supply:
- Disconnect the PC from your power supply.
- Pull the voltage connector out of the IEC socket of the PC.
Proceed as follows to disconnect the 24 VDC power supply:
- Disconnect the PC from your power supply.
- Press the latches on the voltage connector together and pull it out of the PC.
- Remove the power supply cable if the connector is to remain with the PC.
Disconnecting cables
To disconnect the cables from the industrial PC, proceed as follows:
- Make a note of the wiring configuration, if you wish to restore it with another device.
- Disconnect the data transmission cables from the industrial PC.
- Finally, disconnect the grounding strap.