Connecting the 24 V power supply
As an alternative to the 100-240 V AC power supply unit in the basic configuration, you can order the industrial PC with a 24 V DC power supply unit. The options C9900-P229 are available to you.
Connect power supply via 24 V DC power supply unit
Cables with a maximum cable cross-section of 4 mm2 can be used for connecting the power supply. For long supply lines, use 4 mm2 cables to achieve a low voltage drop on the supply line. There should be at least 22 V at the voltage connector of the industrial PC, so that the PC remains switched on during voltage fluctuations.
Proceed as follows to connect the 24 V DC power supply unit:
- Install the power supply cable (see the following section "Mounting the supply line").
- Plug the power supply cable into the voltage socket of the industrial PC.
- Connect the industrial PC to your external 24 V power supply.
- Switch on the 24 V power supply.
Before you can connect the power supply, you must install the power supply line yourself. For this purpose, use the supplied material for connector assembly. This consists of the 3-pin connector and the strain relief housing.
Mounting the supply line
First mount the plug on the cable as follows:
- 1. Remove the insulation from the cable ends (8-9 mm).
- 2. Plug the cable ends into the connector strip by simply pressing them in. For the pin assignment of the connector, see Chapter Power supply. In the case of fine-core cables, you must use ferrules.
- You have fitted the supply line to the plug.
Assembly of strain relief housing
Now fit the strain relief housing to the already connected plug and supply line:
- 1. Insert the plug into the open strain relief housing with the cable leading up to the edge. Make sure that the pin numbering on the plug points in the same direction as the sticker on the strain relief housing (section A).
- 2. Press the plug against the underside of the strain relief housing until it clicks into place.
- 3. Press the top of the strain relief housing onto the lower part until the tabs have slipped over the latching lugs (section B).
- 4. Tighten the M2 screw on the side (section C).
- You have mounted the strain relief housing.
To dismantle the strain relief housing, proceed as follows:
- 1. Release the M2 screw on the side (section A).
- 2. Use your fingers to bend the five tabs slightly outwards (section B).
- 3. Pull the upper section off the lower section until the tabs slide over the latching lugs (section C).
- 4. Pull the plug out of the strain relief housing (section D).
- You have dismantled the strain relief housing.