Access to device components

To be able to replace certain device components, you must first gain access to the interior of the industrial PC.

Be sure to shut down the device and switch it off before replacing NVMe™ M.2 SSDs.

To do this, follow the steps:

1. Pull the release handle upward to release the housing cover lock (section A).
2. Pull the housing cover forward by the handle until it moves freely at the bottom (section B). While doing so, hold the cover firmly so that it does not fall off.
Access to device components 1:Fig.30: Unlocking the housing cover
3. Guide the housing cover downwards out of the guides (section C).
4. Loosen the knurled screw (1) of the card locating holder (2) (section D).
Access to device components 2:Fig.31: Access to the interior of the device
5. Remove the card locating holder from the housing.
You now have access to the interior of the industrial PC.

To reinstall the card locating holder afterwards, follow the steps below:

1. Release all plastic elements of the card locating holder (section A).
2. Place the card locating holder again in the slots provided in the industrial PC (section B).
3. Keep the card locating holder pressed onto the edge of the industrial PC while tightening the knurled screw again (section C).
Access to device components 3:Fig.32: Mounting the card locating holder
4. For each plug-in card, press down the associated plastic element of the card locating holder until the plug-in card is firmly seated in its slot.
You have mounted the card locating holder.

To reassemble the housing cover to the PC, you must push the inner hooks (1) of the housing cover into the guides (2) of the housing.

Access to device components 4:Fig.33: Hooks and guides

To do this, follow the steps below:

1. Hold the cover inclined and place it below the housing (section A).
2. Push the cover up as far as possible, inserting the hooks of the cover into the guides of the housing (2) (section B).
3. Place the cover into a straight position against the housing until the release handle snaps back into place (section C).
You have mounted the cover on the housing.
Access to device components 5:Fig.34: Mounting the housing cover