Disconnecting the power supply and cables

CAUTION

Risk of electric shock

Dangerous touch voltages can lead to electric shock. To avoid electric shock, observe the following:

  • Never connect or disconnect the device cables during a thunderstorm.
  • Provide protective earthing for handling the device.

Before disassembling the device, you must disconnect the cables and the power supply. Follow the steps below:

1. Shut down the operating system.
2. Disconnect the device from your external 24 V power supply.
3. Pull the power plug out of the power supply socket.
4. Make a note of the wiring of all data transmission cables if you want to restore the cabling with another device.
5. Disconnect all data transmission cables from the device.
6. Finally, disconnect the ground connection.
You have disconnected the cables and power supply.