Ethernet RJ45
The C6043 has six Gigabit LAN ports (X102-X107). The Ethernet standards 100Base-T and 1000Base-T enable the connection of corresponding network components and data rates of 100/1000 MBit/s for X102 (LAN1). The Ethernet standards 100Base-T, 1000Base-T and 2500Base-T allow for X103-X107 (LAN2-LAN6) the connection of corresponding network components and data rates of 100/1000/2500 Mbit/s. The required speed is selected automatically.
The RJ45 connection technology with twisted-pair cables is used. The maximum length of the cable connection is 100 m.
Intel® i219 (PHY) for LAN1 and Intel® i226 for LAN2-LAN6 are used as controllers.
The Ethernet ports (X103-X107, LAN2-LAN6) connected via PCIe® with the i226 controller are suitable for cycle times <= 1 ms and for distributed clock applications with EtherCAT.
The Ethernet port (X102, LAN1) integrated in the chipset with the i219 controller is suitable for real-time Ethernet applications with cycle times > 1 ms (without distributed clocks).
Pin | Signal | Description |
|---|---|---|
1 | T2 + | Pair 2 |
2 | T2 - | |
3 | T3 + | Pair 3 |
4 | T1 + | Pair 1 |
5 | T1 - | |
6 | T3 - | Pair 3 |
7 | T4 + | Pair 4 |
8 | T4 - |
The LEDs of the LAN interfaces indicate the activity and the data transmission rate (Mbit/s). The LED (LINK/ACT) highlighted completely green in the figure indicates whether the interface is connected to a network. If this is the case, the LED lights up green. The LED flashes green when data transmission is in progress on the interface.
The green/orange LED (SPEED) shown in the figure indicates the data transmission rate.
The meanings of the LEDs at LAN1 and LAN2-LAN6 differ due to the possible data transmission rate as follows:
Interface | Mbit/s | LED |
|---|---|---|
LAN1 | 100 | Lights up orange |
1000 | Lights up green | |
LAN2-LAN6 | 100 | Is not lit |
1000 | Lights up orange | |
2500 | Lights up green |