Fan access
The device has a total of four fans: two on the bottom and two on the left side of the device. Before you can replace the fans, you must gain access to them. You will first have access to the fans on the bottom and then to the fans on the left side.
To gain access to the fans, follow the steps below:
- 1. Remove the two M2.5 screws from the graphics card cover and the blank cover (section A).
- 2. Remove the graphics card cover and the blank cover (section A).
- 3. Remove the four M3 screws from the right side panel (section B).
- 4. Remove the cover on the right side (section B).
- You now have access to the fans on the bottom of the device.
- 5. Remove the four M2.5 screws on the top and bottom of the device (section C).
- 6. Remove the cover on the left side (section C).
- You now have access to the fans on the left side (section D).