USB

The industrial PC has four USB interfaces (X106-X109). They are used to connect peripheral devices with USB interfaces. The following table shows the interface assignment based on the device generation:

USB interfaces based on device generation

Device generation

USB interfaces

C6032-0060

4x USB 3.0 (X106-X109)

C6032-0070

4x USB 3.0 (X106-X109)

C6032-0080

2x USB 3.2 Gen 2 (X108-X109)

2x USB 3.2 Gen 1 (X106-X107)

Each of the four USB interfaces supplies up to 900 mA of current and is electronically protected. USB ports A and B and USB ports C and D are each protected by a common overcurrent protection. If an overcurrent occurs at one of the ports, the two jointly protected USB ports are switched off.

For the device generation C6032-0070, USB port X108 is only compatible with USB 3.0.

USB 1:
Fig.4: USB interface pin numbering
USB interface pin assignment

Pin

Assignment

1

Vbus

2

D -

3

D +

4

GND

5

StdA_SSRX -

6

StdA_SSRX +

7

GND_DRAIN

8

StdA_SSTX -

9

StdA_SSTX +