Replacing the fan

Notice

Incorrect fan type

The device may be damaged if the wrong type of fan is installed.

  • Only replace the fans with replacement fans from Beckhoff Service.

The fans ensure optimal cooling of the device. Order replacement fans only from Beckhoff. Please get in touch with your Beckhoff sales contact.

Before you can access the fan, you must remove the side cover. Follow the instructions in Chapter 7.2 Maintenance.

To replace the fan, follow the steps below:

1. Remove the four Torx TX10 screws at the top and bottom of the industrial PC (section A).
2. Remove the fan housing (section B).
3. Remove the two Torx screws to detach the fan from the fan plate (section C).
Replacing the fan 1:Fig.41: Fan access
4. Disconnect the fan power cable from the motherboard and pull it out of the cable sleeve.
You can now replace the fan.
5. Pull the supply cable of the new fan through the cable sleeve and plug it into the motherboard.
6. Attach the fan to the fan plate with the two Torx screws and a tightening torque of approx. 0.5 Nm.
You have successfully replaced the fan.

The old fan must be disposed of in accordance with the national electronic waste regulations.