Control cabinet installation
Notice | |
Extreme environmental conditions Extreme environmental conditions can cause damage to the device.
|
Notice | |
Incorrect installation Incorrect installation in a control cabinet prevents air circulation in the device and causes impaired functioning.
|
The device is designed for installation inside a control cabinet in machine and system engineering. The environmental conditions specified for operation must be observed.
Using different mounting plates, you can align the cable entry based on the application requirements.
The following figure shows the three available mounting plates: standard mounting plate 1, optional mounting plate 2, and optional mounting plate 3 with DIN rail adapter. The three mounting plates are mounted on the device as follows:
- Mounting plate 1: at the rear of the industrial PC with three Torx TX10 screws and a tightening torque of approx. 0.5 Nm
- Mounting plate 2: on the right-hand side panel of the industrial PC with four Torx TX10 screws and a tightening torque of approx. 0.5 Nm
- Mounting plate 3: at the rear of the industrial PC with two Torx TX10 screws and a tightening torque of approx. 0.5 Nm
Mounting plate 2 offers two mounting options (see Chapter 4.2.1 Mounting options).
The basic version of the industrial PC is supplied with the standard mounting plate 1 already mounted. The scope of delivery does not include any further mounting plates. You can choose the following ordering options:
Order identifier | Version |
|---|---|
C9900-M682 | Mounting plate for C602x on the side wall, instead of the standard mounting plate |
C9900-M683 | Mounting plate for lateral mounting of the C602x, single part, not mounted |
C9900-M684 | Mounting plate with DIN rail adapter for C602x, instead of the standard mounting plate |
C9900-M685 | Mounting plate with DIN rail adapter for C602x, single part, not mounted |