Control cabinet installation
Notice | |
Extreme environmental conditions Extreme environmental conditions can cause damage to the device.
|
Notice | |
Incorrect installation Incorrect installation in a control cabinet prevents air circulation in the device and causes impaired functioning.
|
The device is designed for installation inside a control cabinet in machine and system engineering. The environmental conditions specified for operation must be observed.
The following figure shows the three available mounting plates: standard mounting plate 1, optional mounting plate 2, and optional mounting plate 3 with DIN rail adapter. The three mounting plates are mounted on the device as follows:
- Mounting plate 1: at the rear of the industrial PC with three Torx TX10 screws and a tightening torque of approx. 0.5 Nm
- Mounting plate 2: on the right-hand side panel of the industrial PC with four Torx TX10 screws and a tightening torque of approx. 0.5 Nm
- Mounting plate 3: at the rear of the industrial PC with two Torx TX10 screws and a tightening torque of approx. 0.5 Nm
Mounting plate 2 offers two mounting options (see Chapter 4.2.1 Mounting options).
Order identifier | Version |
|---|---|
C9900-M682 | Mounting plate for C602x on the side wall, instead of the standard mounting plate |
C9900-M683 | Mounting plate for lateral mounting of the C602x, single part, not mounted |
C9900-M684 | Mounting plate with DIN rail adapter for C602x, instead of the standard mounting plate |
C9900-M685 | Mounting plate with DIN rail adapter for C602x, single part, not mounted |