Disassembly and disposal

Before you can remove the device from the control cabinet, you must first disconnect the power supply and the cables (see Chapter Disconnecting the power supply and cables).

Disassembly with mounting plates

To remove the industrial PC from the control cabinet via Standard mounting plate 1 or optional mounting plate 2, proceed as follows:

1. Loosen the fastening screws just enough so that they remain attached to the control cabinet.
2. Lift the PC until the fastening screws slide into the keyholes.
Disassembly and disposal 1:Fig.19: Positions of the fastening screws
3. Remove the PC from the control cabinet.
You have successfully disassembled the PC.

Disassembly with DIN rail adapter

To remove the industrial PC from the control cabinet via optional mounting plate 3 with the DIN rail adapter, follow the steps below:

1. Push the PC upwards to press in the spring contacts on the DIN rail adapter (A).
2. Unhook the upper side of the adapter from the DIN rail (B).
3. Also unhook the lower side of the adapter from the DIN rail.
You have successfully removed the industrial PC from the control cabinet.
Disassembly and disposal 2:Fig.29: Disassembly of the DIN rail adapter

Disposal

When disposing of the device follow the national electronic scrap regulations. In order to dispose of the device, it must be removed and fully dismantled. Dispose of the components in the following way: