Technical data

Technical data

Product designation

C6015

Dimensions (W x H x D)

82 x 82 x 40 mm, without mounting plate

Weight

approx. 400 g without mounting plate

approx. 450 g with mounting plate

Supply voltage

22-30 VDC (24 VDC power supply unit) NEC Class 2

Power consumption

Data sheet power consumption and power loss in the download finder:

https://www.beckhoff.com/en-en/support/download-finder/search-result/?download_group=691754572

Secure element

fTPM 2.0 enabled (see TPM manual)

Protection rating

IP20

Vibration resistance (sinusoidal vibration)

EN 60068-2-6: 10 to 58 Hz: 0.035 mm

58 to 500 Hz: 0.5 G (approx. 5 m/ s2)

Shock resistance (shock)

EN 60068-2-27: 5 G (approx. 50 m/s2), duration: 30 ms

EMC interference immunity

conforms to EN 61000-6-2

EMC interference emission

conforms to EN 61000-6-4

Permissible ambient temperature

0 °C to +50 °C (operation)

-25 °C...+65 °C (transport / storage)

Permissible air humidity

Maximum 95 %, no condensation

Transport and storage