Example
ST sample program
 Download (sample file)
 Download (sample file)
PROGRAM MAIN
VAR
(* EXAMPLE - BRIDGE between PIN 7 and 8 from X01 COM 2 Port*)
fb_COMPortOpen_1 : FB_COMPortOpen;
stCOMConfig_1 : ST_COMConfig;
hCOM : WORD;
Result_R : INT;
Result_W : INT;
Var_M : ARRAY[0..9] OF BYTE:=11,22,0,33,0(6);
Var_R : ARRAY[0..9] OF BYTE;
Value : INT;
Counter_V : BYTE; (* It is all OK, this value counts up *)
i : INT;
i_k : INT;
fbTimer : TON;
END_VAR
stCOMConfig_1.cbRxBufferLen :=300;
stCOMConfig_1.cbTxBufferLen :=300;
stCOMConfig_1.dwMode :=0;
stCOMConfig_1.BaudRate :=19200;
stCOMConfig_1.eCommPort :=COM2;
stCOMConfig_1.eDataBits:=EIGHT_DATABITS;
stCOMConfig_1.eParity:=EVEN;
stCOMConfig_1.eStoppBits:=ONE_STOPPBIT;
CASE i OF
(* Open Port *)
0: fb_COMPortOpen_1(bOpen:=TRUE , stCOMConfig:=stCOMConfig_1);
IF NOT fb_COMPortOpen_1.bBusy THEN
IF NOTfb_COMPortOpen_1.bError THEN
hCOM:=fb_COMPortOpen_1.iHandle ;
i:=i+1;
ELSE
i:=100;
END_IF
END_IF
(* Write data*)
1: fbTimer(IN:=FALSE);
Result_W:=F_COMPortWrite(hCom, 4,ADR(Var_M[0]));
IF Result_W>0 THEN
i:=i+1;
Var_M[2]:=Var_M[2]+1;
ELSE
i:=101;
END_IF
(*Receive data*)
2: Result_R:=F_COMPortRead(hCom, 100,ADR(Var_R[Value]));
IF Result_R<>0 THEN
Value:=Result_R+Value;
END_IF
IF Value>=4 THEN
FOR i_k:=0 TO Value DO(*Check protocol*)
IF Var_R[i_k-4]=11 AND Var_R[i_k-3]=22 AND Var_R[i_k-1]=33 THEN
Counter_V:=Var_R[i_k-2];
i:=1;
Value:=0;
END_IF
END_FOR
END_IF
fbTimer(IN:=TRUE,PT:=t#1s); (*Watchdog receive*)
IF fbTimer.Q THEN
fbTimer(IN:=FALSE);
i:=102;
END_IF
100: ; (*ERROR open port*)
101: ; (*ERROR send data*)
102: i:=1; (*WD ERROR no data receive*)
END_CASE