Cable colors
Suggested method of using the Beckhoff CAN cable on Bus Terminal and Fieldbus Box:
|
BK51x0 pin |
Pin BK5151 CX8050, CX8051, |
Fieldbus Box pin |
Pin FC51xx |
Function |
ZB5100 cable color |
ZB5200 cable color |
|---|---|---|---|---|---|---|
|
1 |
3 |
3 |
3 |
CAN Ground |
black/ (red) |
black |
|
2 |
2 |
5 |
2 |
CAN Low |
black |
blue |
|
3 |
5 |
1 |
5 |
Shield |
Filler strand |
Filler strand |
|
4 |
7 |
4 |
7 |
CAN high |
white |
white |
|
5 |
9 |
2 |
9 |
not used |
(red) |
(red) |