Installing Beckhoff RT Linux®
Connect the boot-capable USB stick with Beckhoff RT Linux® image to an industrial PC and start the device.
Prerequisites:
- Bootable USB stick with Beckhoff RT Linux® image.
- Min. 4 GB free space on the memory card.
Proceed as follows:
- 1. Connect the USB stick with Beckhoff RT Linux® image to the industrial PC.
- 2. Start the industrial PC and press [F7] to enter the boot menu.
- 3. Select the UEFI entry for the USB stick and confirm with [Enter].
The industrial PC boots from the USB stick and the Beckhoff installer is executed. - 4. Select the TC/LUR Install option to install Beckhoff RT Linux®.

- 5. Select the appropriate hard disk as the destination for the installation.

- 6. Enter a password and follow the further installation instructions.

- Restart the industrial PC. Beckhoff RT Linux® is loaded.