DC

This tab can be used for the distributed clock settings. The EtherCAT slave can be operated in FreeRun mode or DC Synchronous mode.

DC 1:


No.

Description

1

Here you can change the settings for the Operation mode. You can choose between FreeRun and DC Synchronous mode.

2

The Advanced Settings button opens a further window with additional settings for the distributed clocks function.


EtherCAT slaves feature integrated local clocks, which are synchronized by the EtherCAT master via special datagrams. For sample, the local clock of an EtherCAT slave can be used as reference clock, based on which all other clocks are synchronized.

By default, TwinCAT sets the first EtherCAT slave that supports the distributed clocks function as reference clock. This setting can be changed, although we recommend retaining the default setting.