32E0:04 Status

Status register of the EnDat2.2 motor feedback system. - Bit 0: PositionReady - Bit 1: PositionTimeout - Bit 2: EnDat22Status_Error1 - Bit 3: EnDat22Status_Crc - Bit 4: EnDat22Status_ErrorHandlerType1active - Bit 5: EnDat22Status_ErrorHandlerType2active - Bit 6: EnDat22Status_MrsAdrError - Bit 7: EnDat22Status_NotError2 - Bit 8: EnDat22Status_CrcErrorZ1 - Bit 9: EnDat22Status_CrcErrorZ2 - Bit 10: EnDat22Status_ReferenceLatched - Bit 11: EnDat22Status_Warning - Bit 12: EnDat22Status_ErrorHandlerType3active - Bit 13: reserved - Bit 14: reserved - Bit 15: reserved

Description

Value

Index

PrimaryFeedbackSlot: 0x32E0 (Ch A)
SecondaryFeedbackSlot: 0x3300 (Ch A)

Subindex

0x04

Datatype

UINT16

Min. Value

 

Default

 

Max. Value

 

Unit

 

Access / EtherCAT-State

Ro

PDO Mapping

Transmit / Dynamic Transmit

Revision

All