60E9:01 1st additional feed constant - feed

This sub-index contains the value for the first additional encoder. (The first additional encoder is the second encoder.)

Description

Value

Index

0x60E9 (Ch A)

Subindex

0x01

Datatype

ENUM (UINT32)

Min. Value

 

Default

eFeedConstant_2Pow20 (1048576)

Max. Value

 

Unit

 

Access / EtherCAT-State

Rw

PDO Mapping

 

Revision

All

Enum Value

Description

0 (0x00000000)

eFeedConstant_2Pow32

2147483648 (0x80000000)

eFeedConstant_2Pow31

1073741824 (0x40000000)

eFeedConstant_2Pow30

536870912 (0x20000000)

eFeedConstant_2Pow29

268435456 (0x10000000)

eFeedConstant_2Pow28

134217728 (0x08000000)

eFeedConstant_2Pow27

67108864 (0x04000000)

eFeedConstant_2Pow26

33554432 (0x02000000)

eFeedConstant_2Pow25

16777216 (0x01000000)

eFeedConstant_2Pow24

8388608 (0x00800000)

eFeedConstant_2Pow23

4194304 (0x00400000)

eFeedConstant_2Pow22

2097152 (0x00200000)

eFeedConstant_2Pow21

1048576 (0x00100000)

eFeedConstant_2Pow20

524288 (0x00080000)

eFeedConstant_2Pow19

262144 (0x00040000)

eFeedConstant_2Pow18

131072 (0x00020000)

eFeedConstant_2Pow17

65536 (0x00010000)

eFeedConstant_2Pow16

1000000 (0x000F4240)

eFeedConstant_10Pow6

100000 (0x000186A0)

eFeedConstant_10Pow5

10000 (0x00002710)

eFeedConstant_10Pow4

1000 (0x000003E8)

eFeedConstant_10Pow3

100 (0x00000064)

eFeedConstant_10Pow2

10 (0x0000000A)

eFeedConstant_10Pow1

1 (0x00000001)

eFeedConstant_10Pow0