73C2, EnDat22: Encoder start failed, Id=0xXX, Arg=0xXX
The start sequence of the encoder processing failed:
Id=0x01: Enocder start failed with internal error code (Arg='Internal error code'')
Id=0x08: Encoder file processing error. Arg=Internal Id
Id=0x0C: Encoder start failed. Start sequence aborted in step = 'Arg'
Id=0x0D: Encoder start failed. Arg=1: Pointer not allocated, Arg=2: Invalid Fpga, Arg=3: Internal error, Arg=4: MeasuringStepsPerRev or MeasuringStepLength == 0, Arg=5: Internal error, Arg=6: Init position processing failed, Arg=7: MeasuringStepsPerRev or MeasuringStepLength == 0
|
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
|---|---|
|
73C2 |
29634 |
|
Class |
Type |
|---|---|
|
Error |
Feedback error |
|
Standard Reaction |
Reset |
|---|---|
|
Axis is inoperable |
Execute Reset-Command (Fault reset). |
|
Possible Causes |
Solutions |
|---|---|
|
|
|
Internal: 0x73C2, EnDat22: Encoder start failed, Id=0x%X, Arg=0x%X