8A82, Error reaction "NC Handling" had a timeout
With NC error handling activated (Fault reaction option code), the Drive was not stopped by the NC within the parametrized time period (Error reaction delay time).
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
---|---|
8A82 |
35458 |
Class |
Type |
---|---|
Error |
Error |
Standard Reaction |
Reset |
---|---|
Closed loop ramp |
Execute Reset-Command (Fault reset). |
Possible Causes |
Solutions |
---|---|
The selected time period is too short. |
Increase the time period if your application allows this. |
The movement is too complex for the parametrized time period. |
Program a movement that is suitable for the time period. |
The NC doesn't support this kind of error handling. |
Ask support on which version the feature is supported. |
Internal: 0x8A82, Error reaction "NC Handling" had a timeout