63B7, Modulo calculation primary feedback: The absolute range of encoder is too small or incompatible
Modulo calculation primary feedback: The absolute range of encoder is too small.
|
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
|---|---|
|
63B7 |
25527 |
|
Class |
Type |
|---|---|
|
Error |
Error |
|
Standard Reaction |
Reset |
|---|---|
|
Axis is inoperable |
Execute Reset-Command (Fault reset). |
|
Possible Causes |
Solutions |
|---|---|
|
The modulo calculation with data storage can only be used if a multi-turn feedback is connected. |
Connect and use a multi-turn feedback. |
|
The modulo calculation with data storage can only be used if a rotary feedback is connected. |
Connect and use a rotary feedback and motor. |
Internal: 0x63B7, Modulo calculation primary feedback: The absolute range of encoder is too small or incompatible