8481, Error reaction "Closed loop ramp" had a timeout

A closed loop error reaction was aborted because of a timeout.

Diagnostic Code (Hex.)

Diagnostic Code (Dez.)

8481

33921

Class

Type

Error

Error

Standard Reaction

Reset

Shorted coils brake

Execute Reset-Command (Fault reset).

Possible Causes

Solutions

The control loop wasn't able to create enough torque for the deceleration.

Increase quick stop deceleration value.

The control loop wasn't able to create enough torque for the deceleration.

Check the torque limiting parameters.

The axis is humming and standstill wasn't detected.

Check control parameters to reduce humming.

The axis is humming and standstill wasn't detected.

Adjust standstill detection parameters, velocity threshold and velocity threshold time.


Internal: 0x8481, Error reaction "Closed loop ramp" had a timeout