3183, The bipolar velocity limit is higher than 1/4 of position range limit per EtherCAT Sync1 cycle.

The maximum accepted position step per cycle is 1/4 of the position range limit range. This error occurs, if the resulting velocity is lower than the bipolar velocity limit.

Diagnostic Code (Hex.)

Diagnostic Code (Dez.)

3183

12675

Class

Type

Error

Error

Standard Reaction

Reset

Nc handling

Execute Reset-Command (Fault reset).

Possible Causes

Solutions

The maximum accepted position step per cycle is 1/4 of the position range limit range. This error occurs, if the resulting velocity is lower than the bipolar velocity limit.

Raise your position range limit or lower your bipolar velocity limit.


Internal: 0x3183, The bipolar velocity limit is higher than 1/4 of position range limit per EtherCAT Sync1 cycle.