63A9, Position range limit Inc with remainder is not supported for secondary feedback.
The position range limit is scaled internally to encoder increments. This calculation result contains a remainder, which is not supported for the secondary feedback.
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
---|---|
63A9 |
25513 |
Class |
Type |
---|---|
Error |
Error |
Standard Reaction |
Reset |
---|---|
Axis is inoperable |
Execute Reset-Command (Fault reset). |
Possible Causes |
Solutions |
---|---|
The position range limit is scaled internally to encoder increments. This calculation result contains a remainder, which is not supported for the secondary feedback. |
Please check the position range limit and the factor group parameters of this feedback. |
Internal: 0x63A9, Position range limit Inc with remainder is not supported for secondary feedback.