AX8820 universal regenerative unit

Electrical data

AX8820-0070-0000

Function

Regenerative unit

Nominal supply voltage

3 x 360 … 520Y/300 V

Nominal supply current [AAC]

10.1

Peak output current for 60 seconds [AAC]

15.2

Frequency [Hz]

50/60

Mains filter

Integrated, category C2

SCCR value [kA]

5

Minimum DC link capacitance of the connected devices [µF]

235

Nominal output [kW]

7

Basic power loss and power-dependent power loss

Basic power loss with fan switched off [W]

3.49

Basic power loss with fan switched on [W]

11.48

Power-dependent power loss at 400 VAC [W/kW]

22

Power-dependent power loss at 480 VAC [W/kW]

24

DC link

DC link voltage [VDC]

max. 848

24 V control voltage [VDC]

18 … 30

24 V current consumption [ADC]

0.7

 

Product characteristics

AX8820-0070-0000

System bus

EtherCAT

Drive profile

CiA402 according to IEC 61800-7-201 (CoE)

Ambient temperature (operation)

0...+45 °C, up to +55 °C with power derating (see documentation)

Approvals/markings

CE

 

Mechanical data

AX8820-0070-0000

Width [mm]

90

Height without connectors [mm]

230

Depth without connectors / accessories [mm]

186.5

Weight [kg]

3.2