7181, Brake resistor power overload by DC link over-voltage. Operating time counter: UU s., Entry counter: UU
Brake resistor was disabled because of power overload. As result over-voltage at dc link.
Diagnostic Code (Hex.) |
Diagnostic Code (Dez.) |
---|---|
7181 |
29057 |
Class |
Type |
---|---|
Error |
Error |
Standard Reaction |
Reset |
---|---|
Non-generative brake ramp order to the axis |
Execute Reset-Command (Fault reset). |
Possible Causes |
Solutions |
---|---|
Your application is so designed, that the brake energy overloads the brake resistor. |
Analize your application and make, that this overload does not happen or connect a more powerful brake resistor if possible. |
Internal: 0x7181, Brake resistor power overload by DC link over-voltage. Operating time counter: %u s., Entry counter: %u