Object description
In the following you will find information about which CoE objects are involved in the function. The configuration is always dependent on the application and environmental and operational conditions.
CoE object | Designation | Description |
---|---|---|
Channel A 0x60E0 Channel B 0x68E0 | Positive torque/force | This object indicates the configured maximum positive torque/force in the motor. The value shall be given per thousand of standstill torque/force (0x6076). Positive torque/force takes effect in the case of motive operation is positive velocity or regenerative operation is negative velocity.
|
Channel A 0x60E1 Channel B 0x68E1 | Negative torque/force | This object indicates the configured maximum negative torque/force in the motor. The value shall be given per thousand of standstill torque/force (0x6076). Negative torque/force takes effect in the case of motive operation is negative velocity or regenerative operation is positive velocity.
|
Channel A 0x6072 Channel B 0x6872 | Bipolar torque/force | This object indicates the con_gured maximum bipolar permissible torque/force in the motor. The value shall be given per thousand of standstill motor torque/force (0x6076).
|