Configuration
The digital inputs can be configured differently via the TC3 Drive Manager 2. The lower part of the "Basic settings" tab contains the selection menu for the digital inputs.
![Configuration 1:](Images/png/10035313291__Web.png)
The selection menu may differ depending on the AX8000 device (AX8xxx-x0xx, AX8xxx-x1xx, AX8xxx-x2xx). For devices with safety functionality, the top two inputs are preset as safe inputs and cannot be used for other functions (limit switch, touch probe, hardware enable).
AX8xxx-x0xx Device without Safety / Digital input 1 and 2 can be used additionally
![Configuration 2:](Images/png/10035317259__Web.png)
AX8xxx-x2xx device with Safety / Digital input 1 and 2 are preassigned Safety inputs
![Configuration 3:](Images/png/10035319947__Web.png)
The activation of the functions is done by checking the appropriate box. In the following picture, for example, a positive limit switch and a touch probe. The logic of the switch can be changed by selecting the buttons below the tick. (break contact / make contact)
![Configuration 4:](Images/png/10035322507__Web.png)
If you use an input as hardware enable you have the choice between the reaction "Torque off" or "Closed Loop Ramp".
![Configuration 5:](Images/png/10035383819__Web.png)
The state of the inputs is indicated online by the red (level low) or green (level high) button.
![Configuration 6:](Images/png/10035325323__Web.png)