Combined power supply modules and axis modules AX8525, AX8540
Electrical data | Combined power supply modules and axis modules 25 A | Combined power supply modules and axis modules 40 A |
|---|---|---|
AX8525-0xx0 | AX8540-0xx0 | |
Mains supply | ||
Rated input current at 40 °C [AAC] | 70 | |
Maximum rated input current [AAC] | 140 | |
Rated supply voltage [VAC] | 3 x 200 / 480 | |
Mains filter | Integrated; category C3 | |
SCCR value [kA] | 65 | |
System and peripheral voltage supply | ||
24 V system voltage and peripheral voltage [V] | 24 V DC +6/-10 % | |
24 V current consumption without holding brake [mA] | 750 | |
Maximum current brake output [mA] | 2000 | |
permissible sum current of all connected | 20 | |
Rated output power | ||
At 400 VAC mains connection voltage [kW] | 42.8 | |
Basic power loss and power-dependent power loss | ||
Basic power loss [W] | 18 | |
Power-dependent power loss at 230 VAC | 4 W/kW + 8 W/A | |
Power-dependent power loss at 400 VAC | 4 W/kW + 10 W/A | |
Power-dependent power loss at 480 VAC | 4 W/kW + 11 W/A | |
Example: With a rated input power of 20 kW and a motor current from the directly connected motor of 8 A, the total power loss is | ||
DC link | ||
Maximum voltage [VDC] | 848 | |
Capacitance [µF] | 1520 | |
Rated output current [ADC] | 80; of which maximum 50 to the AX-Bridge | |
Maximum rated output current [ADC] | 160; of which maximum 100 to the AX-Bridge | |
Integrated axis module | ||
Current resolution [Inc/A] | 144,8 | |
Output current at 400 VAC mains connection voltage | ||
Rated output current [A]; 8 /16 kHz | 25 / 14 | 40 / 23.5 |
Peak output current Irms [A] | 50 / 23 | 80 / 37.5 |
Output current at 480 VAC mains connection voltage | ||
Rated output current [A]; 8 /16 kHz | 25 / 13 | 40 / 21 |
Peak output current Irms [A] | 50 / 19 | 80 / 30.5 |
Electrical data | Combined power supply modules and axis modules 25 A | Combined power supply modules and axis modules 40 A |
|---|---|---|
AX8525-0xx0 | AX8540-0xx0 | |
Output frequency | ||
Output frequency of the limited standard version [Hz] | 0…599 | |
Output frequency of the dual-use version [Hz] | 0…1600 | |
Internal braking resistor | ||
Continuous braking power [W] | 200 | |
Maximum braking power [kW] | 68 | |
External braking resistor | ||
Minimum resistance value [Ω] | 10 | |
Continuous braking power [kW] | 6 | |
Maximum braking power [kW] | 68 | |
Mechanical data | Combined power supply modules and axis modules 25 A | Combined power supply modules and axis modules 40 A |
|---|---|---|
AX8525-0xx0 | AX8540-0xx0 | |
Width [mm] | 360 | |
Height [mm] | 230 | |
Depth [mm] | 192 | |
Weight [kg] | 15 | |