Control cabinet structure
![]() | Observe the voltage tolerances for safe operation When connecting servomotors with a holding brake, observe the prescribed voltage tolerances. Observe the order of connection The nominal current of the device should reduce from the power supply module. Beckhoff recommends the following order of connection of the modules:
|
You must dimension the control cabinet in such a way that you can install all components with the prescribed spacing.
Forced cooling must be used in case of high temperatures. Place the control cabinet as close as possible to the machine. Dimension the motor cables as short as possible. Apart from that, the control cabinet must have a metallic, grounded rear panel, to which the AX8000 and the peripherals are attached. This makes secure grounding possible.