Energy management
If the supply network is impaired due to high voltage fluctuations, you must consider the specifications of the servo drive and the speed range of the servomotor. Observe the upper limit value of the wide voltage input on the AX8000.
Check whether the lowering of the speed due to lacking voltage is permissible.
If the supply network does not correspond to the specification for the operation of the servo drive, then isolating transformers, mains chokes, mains filters or other measures must be added.
This system operates in a drive system with a common DC link and a commonly used internal or external brake resistor. In the case of already existing drive systems, you can determine the utilization rate of the brake resistor with the aid of the diagnostic system and transfer the values. The Beckhoff software "TE5910 | TwinCAT 3 Motion Designer" is available for energy management purposes.